LV SWITCHGEAR (MV Panels)

Providence General Services is offering L&T Make Enersys-M MV Switchgear. Approved by KAHRAMAA and accetable by Major Consultant in Qatar.

The Enersys-M is the perfect solution for commercial and Residential Complex, Hotels, Hospitals, Resorts, Malls and Masjids. Enersys-M provides a blend of latest technology and appealing aesthetics.

Features:

  • Type tested assembly with compliance to IEC 61439-2
  • Copper Busbar
  • Fault withstand capacity up to 50kA for 3Sec
  • Ingress Protection (sometimes refer as International Protection Code) IP Rating up to IP 54
  • Highest Performance Ensured
  • In house site installation team (MV Panel Installation and Cable Termination)
  • Highest Performance Ensured.

 

Mechanical
Characteristic

Degree of Protection

As per IEC 60529

External

IP 4X

IP 54 – UP to 2500A

Internal

IP 2X

Forms of Separation

As per IEC 61439-2

Up to Form 4b

Dimension

Height (mm)

2200

2300 (with Plinth)

Width (mm)

600 (MCCB Compartment with
rear cable access)

900/1000 (MCCB Compartment
with front cable access)

Depth (mm)

800/1000 – up to 2500A

1000 – Above 2500A

Surface Treatment

Structure/Internal/External

Powder Coated/Painted

Resistance to Corrosion

Damp heat cycling test

IEC 60068-2-30

 

 

Salt mist test

IEC 60068-2-11

Plastic Components

Flame Retardant, Self-Extinguishing,
Halogen Free.

IEC 60695-2-10, IEC
60695-2-11

Electrical
Characteristic

Voltage Ratings

IEC 61439

Rated operational voltage (U ) e

415 VAC

Rated insulation voltage (U ) i

upto 1000 VAC

Rated impulse

upto 12 kV

withstand voltage (U ) imp

50 / 60 Hz

Dimension

Main Horizontal
Busbars

Rated current (I ) nA

upto 4000A

Rated peak withstand current (I ) pk

upto 143 kA

Rated short-time withstand current (I )

 

50 kA, 1s

50 kA, 3s

65 kA, 1s

Vertical Distribution
Busbars

Rated current (I )

upto 1800A

Rated peak withstand current (I ) pk

upto 143 kA

Rated short-time

50 kA, 1s

50 kA, 3s

65 kA, 1s

Insulation
Characteristic

 

Clearance

Bus Zone – 25 mm

Other areas – 20 mm

 

Creepage distance

Bus Zone – 25 mm

Other areas – 20 mm

 

Overvoltage category

IV

 

Pollution degree

3

 

Field condition

Inhomogeneous (non-uniform)

Safety First

Noble guardian

Enersys-M is divided into distinct compartments (equipment, busbar, cable and auxiliary) segregated by metallic or non-metallic partitions or barriers, to ensure maximum safety level for your operator.

 

Multi level safety

The specially designed tool operated and pad lockable door knob provides multi-level safety for your personnel.

Trusted bus system

Generous clearances for main busbars and connectors ensure unmatched safety for you. Supports and insulation materials are flame resistant, track resistant and non-hygroscopic.

Environment control

Enersys-M gives you protection against access to hazardous parts, solid foreign bodies and liquids. The innovative design of camlock, hinges offers better control.

Integral safety – arc protection

The complete closed door operation and limitation of fault within a confined area, Enersys-M ensures total safety of operator, equipment and surrounding.

LV Switchgear (MV Panel)

Sub Main Distribution Boards (SMDB)
L&T sub main Distribution Board

Distribution Boards (DB)

L&T Distribution Board

Control Panels

L&T Logo